Features
Integrated intelligent control and applicable to the compressor of one H.P.
Temperature Display
Temperature Control
Defrost by turning off
Value Storing / Self Testing
Technical Data
Range of temperature displayed:-45~+99℃
Range of set temperature:02~+45℃
Accuracy:±1℃
Temperature sensor:NTC ,2m(L)
Compressor relay: N.O. 30A/250VAC
(Can connect 1HP compressor, when overload it needs to connect AC contactor)
Dimension:137(Length)×59(Width)×60(Depth)mm
Mounting hole dimension:112.5(Length)×39.5(Width)mm
Technical Data
Paramete |
Function |
Set range |
Default |
E1 |
Lower setpoint limit |
02℃~E2 |
02℃ |
E2 |
Higher setpoint limit |
E1~45℃ |
10℃ |
E3 |
Temp. hysteresis |
01~10℃ |
06℃ |
E4 |
Comp. start delay time |
0 0~1 0 Min |
5 Min |
E5 |
Offset on room temp. |
-20~20℃ |
00℃ |
F1 |
Max. Defrost duration |
01~60 Min |
20 Min |
F2 |
Defrost interval time |
00~24 Hr |
6 Hr |
F4 |
Display during defrost |
00=Normal display 01 = Last value before defrost |
01 |
PO |
Power Supply setting |
ON=Power supply is valid OFF=Power supply is cancelled |
On |
-