Features
It is an intelligent controller and applicable to the compressor of one HP.
Temperature Display / Temperature Control
Automatic defrost by turning off compressor
High,Low temperature alarm / Value Storing
Fan Control / Self Testing /Parameter Locking
Technical Data
Range of temperature displayed : -45~99℃
Range of set temperature:-40~40℃
Accuracy:±1℃
Temperature sensor:NTC, one sensor,2m(L)
Compressor: N.O. 30A/250VAC
(applicable to one HP Compressor,if more it needs to connect an AC contactor)
Fan: N.O. 8A/250VAC
Dimension:181(Length)×41(Width)×68(Depth)mm
Mounting hole dimension:138(Length)×32.5(Width)mm
Parameters
Paramete |
Function |
Set range |
Default |
E1 |
Lower setpoint limit |
-40℃~Set temp. |
-30℃ |
E2 |
Higher setpoint limit |
Set temp.~40℃ |
30℃ |
E3 |
Temp.hysteresis |
1~20℃ |
5℃ |
E4 |
Comp.start delay time |
0~10Min |
2Min |
E5 |
Offset on room temp. |
-20~20℃ |
0 |
F1 |
Max.Defrost duration |
1~90Min |
20Min |
F2 |
Defrost interval time |
0~24Hr |
6Hr |
F4 |
Display during defrost |
0=Normal display 1 = Last value before defrost |
0 |
C2 |
High temperature alarm |
Set value~49℃~OFF |
40℃ |
C3 |
Low temperature alarm |
OFF~-44℃~Set value |
OFF |
C4 |
Alarm time delay |
1~90Min |
-