搜索
1/1
Number of views:
0
1
Description
Features
Temperature control
Built-in transfromer
Evaporator Fan is in-phase with
comopressor during refrigeration
Evap.fan starts during
defrosting by turning off
Technical Data
Range of temperature displayed :-45~150℃
Range of set temperature: -45~99℃
Accuracy:±1℃
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
Compressor: N.O. 16A/250VAC
Evap.Fan : N.O. 8A/250VAC
Parameters
Parameter
|
Function
|
Set range
|
Defrost
|
E1
|
Lower setpoint limit
|
-45℃~Set temp.
|
-35℃
|
E2
|
Higher setpoint limit
|
Set temp.~99℃
|
20℃
|
E3
|
Temp.hysteresis
|
1~20℃
|
4℃
|
E4
|
Comp.start delay time
|
0~10Min
|
2Min
|
E5
|
Offset on room temp.
|
-10~10℃
|
0℃
|
F1
|
Max.defrost duration
|
1~90Min
|
20Min
|
F2
|
Defrost period
|
0~24Hr
|
6Hr
|
F4
|
Display during defrost
|
0=Nomal display
1=Last value before defrost |
1
|
F6
|
The temp.display delay time after defrost
|
1~30Min
|
10Min
|
Previous
None
Next
None
-
Mandy Lam
Lynn Mai -
Kay
Carmen Chan - Tel (0086)760-88787946