Loading
产品展示
搜索
Search
1/1
Number of views:
0

SF-154

Number of views:
0
Quantity
-
+
1
Description

Features 
Temperature Display/ Temperature Control
Manual, automatic defrost by electric heater
Evap. Fan Control/ Time、temp. setting to end defrost
Value Storing/ Self  Testing /Parameter Locking 

Technical Data 
Range of temperature display:-45~66℃ (-45~150℉)  
Range of set temperature:-45~45℃ (-45~120℉)
Accuracy:±1℃ (±2℉)
Compressor:  N.O.  30A/250VAC
Defrost:   N.O.  30A/250VAC
Evap.Fan:   N.O.  30A/250VAC
Dimension:132(Length)×58(Width)×29(Depth)mm
Mounting hole dimension:113(Length)×39.5(Width)mm 

Parameters 
 

Parameter
Function
Set range
Default
E1
Lower setpoint limit
-45℃/-45℉~Set temp.
-35℃/-31℉
E2
Higher setpoint limit
Set temp.~45℃/120℉
20℃/68℉
E3
Temp.Hysteresis
1~10℃/1~18℉
4℃/7℉
E4
Comp.start delay time
0~10Min
2Min
E5
Offset on room temp.
-20~20℃/-36~36℉
0
E6
Offset on evap.temp.
-20~20℃/-36~36℉
0
F1
Max.defrost duration
1~60Min
20Min
F2
Defrost interval time
0~24Hr
6Hr
F3
Defrost termination temp.
0~20℃/32~68℉
8℃/46℉
F4
Display during defrost
0=Normal display
1=Last value before defrost
0
F5
Fan operating function
0=Parallel with comp.
1=Continuous running except defrost
0
C1
Temperature unit
C=℃?? F=℉
C

 

We could not find any corresponding parameters, please add them to the properties table
Previous
Next

Attachment Download

  • SF-154

    Categories:

    Products

    File size:

    136KB

    Time:

    2020-11-03 09:24:29

    Dependent population:

    All

SF-154
Categories:
Products
File size:
136KB
2020-11-03 09:24:29
Dependent population:
All
Page up