SF-485 速冻柜数显温控器
Product number:1033013916835078144
- Description
-
Features
It is a mini-sized and integrated intelligent controller, can directly control 1HP(include 1 HP)compressor.
Temperature Display/ Temperature Control
Manual, automatic defrost /Main and subsidiary fan control
Two work modes/ Light control/ Value Storing / Self Testing
Technical Data
Range of display and set temperature:
Accuracy:±1℃(±2℉)
Temperature sensor: NTC(B=3380, 10K=25℃), three sensors (for cold-room temp. & defrost control& food sensor),1m(L), (neither positive nor negative)
Compressor: N.O. 30A/250VAC
Defrost: N.O. 10A/250VAC
Door frame heater: N.O. 10A/250VAC
Main, subsidiary Fan: N.O. 5A/250VAC
Light: N.O. 5A/250VAC
Dimension:208(Length)×64(Width)×72.5(Depth)mm
Mounting hole dimension:191.5(Length)×58(Width)
Parameters
Parameter
Function
Set range
Default
E1
Lower set point limit
-45℃/-49℉~set temp.
-35℃/-31℉
E2
Higher set point limit
set temp.~20℃/68℉
10℃/50℉
E11
Mode 1 set temp.
-45~20℃/-49~68℉~OFF
03℃/37℉
E12
Mode 2 set temp.
-45~20℃/-49~68℉~OFF
-18℃/ 00℉
E3
Heat preservation hysteresis
01~20℃/02~36℉
06℃/11℉
E40
Turning on delay time
00~10Min
2Min
E41
Comp. start delay time
00~10Min
2Min
E5
Must stop temp. hysteresis
01~20℃/02~36℉
09℃/16℉
E6
Offset on room temp.
-20~20℃/-36~36℉
00℃/00℉
E7
Offset on food sensor
-20~20℃/-36~36℉
00℃/00℉
E8
Offset on evap. Sensor
-20~20℃/-36~36℉
00℃/00℉
F0
Defrost types
00=turning off defrost 01=heating defrost
02=hot gas defrost
02
F1
Defrost duration
01~60Min
30Min
F2
Defrost interval
00~24Hr
4Hr
F3
Defrost termination temp.
F6~45℃/113℉
08℃/46℉