Features
Temperature display
Temperature control
Defrost type optional
Self testing/Defrost control
Door switch control
Automatic energy saving control
Power switch
Technical Data
Range of temperature displayed:-50℃~150℃(-50~302℉)
Range of set temperature:-50℃~45℃(-50~113℉)
Accuracy:±1℃(1℉)
Temperature sensor: NTC, two sensors, 2 meters (Neither positive nor negative ,white)
Compressor :NO. 30A/250VAC
Defrost: NO. 10A/250VAC
Fan: NO. 8A/250VAC
Light: NO. 8A/250VAC
Dimension:208(Length)×64(Width)×72.5(Depth)mm
Mounting hole dimension:192.5(Length)×58(Width)mm
Parameters
Paramete |
Function |
Set range |
Default |
PAS |
Password |
00~99 |
15 |
E1 |
Lower setpoint limit |
-50℃/-50℉~Set temp. |
-25℃/-13℉ |
E2 |
Higher setpoint limit |
Set temp.~45℃/113℉ |
20℃/68℉ |
E3 |
Temp.hysteresis |
00~40℃/00~72℉ |
04℃/07℉ |
E40 |
Comp.start delay time |
00~10Min |
2Min |
E41 |
Delay starting time |
00~10Min |
2Min |
E5 |
Offset on room temp. |
-20~20℃/-36~36℉ |
00℃/00℉ |
E6 |
Offset on evap. temp |
-20~20℃/-36~36℉ |
00℃/00℉ |
E7 |
Offset on condenser |
-20~20℃/-36~36℉ |
00℃/00℉ |
F0 |
Defrost type |
00=Defrost by turning off comp. 01=Heater defrost 02=Hot gas defrost |
01 |
FF0 |
Hot gas defrost comp. delay starting timeComp. force running time |
00~20Min |
00Min |
FF1 |
Defrost mode |
00=Power on hours 01=Comp. continuously working time |
01 |
F1 |
Max. defrost duration |
01~60Min |
20Min |
F2 |
Defrost interval time |
00~24Hr |
-