Description
Features
Temperature control
Evaporator fan control
Automatic/manual defrost by electric heater
Time/temp. seting to end defrost
Re-start delay/Parameter Locking
Value Storing/Self Testing
Technical Data
Range of temperature displayed : —45~99℃
Range of set temperature: —45~45℃
Accuracy:±1℃
Compressor: N.O. 30A/250VAC
Defrost: N.O. 30A/250VAC
Evap. Fan: N.O. 30A/250VAC
Temperature sensor: NTC, 2m(L)
Dimension:118(Length)×44(Width)×35(Depth)mm
Mounting hole dimension:87(Length)×34.5(Width)mm
Parameters
Parameter
|
Function
|
Set range
|
Default
|
E1
|
Lower setpoint limit
|
-45℃~Set temp.
|
-35℃
|
E2
|
Higher setpoint limit
|
Set temp.~45℃
|
20℃
|
E3
|
Temp.hysteresis
|
1~10℃
|
4℃
|
E4
|
Comp.start delay time
|
0~10Min
|
2Min
|
E5
|
Offset on room temp.
|
-10~10℃
|
0℃
|
E6
|
Offset on evap.temp.
|
-10~10℃
|
0℃
|
F1
|
Max.defrost duration
|
1~60Min
|
20Min
|
F2
|
Defrost interval time
|
0~24Hr
|
6Hr
|
F3
|
Defrost termination temp.
|
0~20℃
|
8℃
|