Description
Features
Temperature Control
Manual/automatic defrost.
Time/temp.setting to end defrost
High,Low temperature alarm
Re-start delay
Self Testing
Parameter Locking
Technical Data
Range of temperature displayed:-45~150℃(-45~302℉)
Range of set temperature:-45~45℃(-45~120℉)
Accuracy:±1℃(±2℉)
Temperature sensing probe: two
Comperssor relay:Normally open 16A/250VAC
Defrost heating wire:Normally open 10A/250VAC
Evaporator fan:Normally open 5A/250VAC
Dimension:77mm(L)×35mm(W)×60mm(D)
Mounting hole dimensio:71mm(L)×29mm(W)
Parameters
Paramete
|
Function
|
Set range
|
Default
|
E1
|
Lower setpoint limit
|
-45℃/-45℉~Set temp.
|
-35℃/-31℉
|
E2
|
Higher setpoint limit
|
Set temp.~100℃/212℉
|
20℃/68℉
|
E3
|
Temp.hysteresis
|
1~20℃/1~36℉
|
4℃/7℉
|
E4
|
Comp.start delay time
|
0~10Min
|
2Min
|
E5
|
Offset on room temp.
|
-20~20℃/-36~36℉
|
0
|
E6
|
Offset on evap.temp.
|
-20~20℃/-36~36℉
|
0
|
E7
|
Offset on condens
|
-20~20℃/-36~36℉
|
0
|
F0
|
Defrost function
|
0=Electric heater
1=Hot gas |
0
|
F1
|
Max.Defrost duration
|
1~60Min
|
20Min
|
F2
|
Defrost interval time
|
0~24Hr
|
4Hr
|
F3
|
Defrost termination temp.
|
0~30℃/32~86℉
|
8℃/46℉
|
F4
|
Display during defrost
|
0=Normal display
1=Last value before defrost |
0
|
F5
|
Fan operating function
|
0=Parallel with comp.
1=Continuous running except defrost
|
0
|
C1
|
Temperature unit
|
℃=Celsius ℉=Fahr.
|
℃
|
C2
|
High temperature alarm
|
C3~100℃/212℉
|
40℃/104℉
|
C3
|
Low temperature alarm
|
-45℃/-45℉~C2
|
-40℃/-40℉
|
C4
|
Alarm delay time
|
1~90Min
|
60Min
|