Loading
产品展示
搜索
Search
1/1
Number of views:
0

ED106

Number of views:
0
Quantity
-
+
1
Description

Features 
Temperature control
Evaporator fan control
Automatic/manual defrost
Defrost by electric heater
Time/temp. seting to end defrost
Re-start delay
Celsius/Fahrenheit degrees 

Technical Data 
Range of temperature display:45150  (45~150)
Range of set temperature:4545  (40~113)
Accuracy:±1(±2)
Compressor: N.O. 16A/250VAC
Defrost: N.O. 10A/250VAC
Evap. Fan: N.O. 5A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
 

Parameters 

 

Parameter

Function

Set range

Default

E1

Lower setpoint limit

-45℃/-45℉~Set temp.

-35℃/-31℉

E2

Higher setpoint limit

Set temp.~45℃/113℉

45℃/113℉

E3

Temp.Hysteresis

1~20℃/1.8~36℉

4.0℃/7.2℉

E4

Comp.start delay time

0~10Min

2Min

E5

Offset on room temp.

-20~20.0℃/-36.0~36.0℉

0

E6

Offset on evap.temp.

-20~20.0℃/-36.0~36.0℉

0

F0

defrost function

0=Electric heater  1=Hot gas

0

F1

Max.defrost duration

1~60Min

20Min

F2

Defrost interval time

0~24Hr

6Hr

F3

Defrost termination temp.

0~30℃/32~86℉

8℃/46℉

F4

Display during defrost

0=Normal display
1=Last value before defrost

0

F5

Fan operating function

0=Parallel with comp.

1 = Continuous running except defrost

0

F6

Dripping time

0~30 Min

2Min

F7

Fan delay start mode

after defrost

0=temperature

1= time

1

F8

Fan delay start time

 after defrosting.

0~10Min

2 Min

F9

Fan start temperature after defrosting(evaporator)

-30~30

-22~86

5

41

C1

Temperature unit

0s=℃    1=

0

We could not find any corresponding parameters, please add them to the properties table
Previous
Next

Attachment Download

  • ED106

    Categories:

    Products

    File size:

    137KB

    Time:

    2020-11-03 08:25:16

    Dependent population:

    All

ED106
Categories:
Products
File size:
137KB
2020-11-03 08:25:16
Dependent population:
All
Page up
1