SF-546N single temperature wine cabinet controller
Features
Mini-sized and integrated intelligent control.
Temperature display/Temperature control
Manual, automatic defrost
Illumination control
Evap.Fan control
Parameter looking
Value storing/Self testing
Technical Data
Range of temperature display: -45~66℃(-45~150℉)
Set temperature factory default:15℃/59℉
Temperature sensor: 2NTC,2m(L), regardless of positive and negative
Compressor: N.O.30A/250VAC
Heater: N.O.10A/250VAC
Light: N.O.8A/250VAC
Evap.Fan: N.O.8A/250VAC
Display panel dimension:208mm(Length) 64mm(Width) 40mm(Depth)
Mounting hole dimension: 192.5mm(Length) × 58mm(Width)
Main frame dimension:150mm(Length)×130mm(Width)×55mm(Depth)
Parameters
Paramete |
Function |
Set range |
Default |
E1 |
Lower setpoint limit |
41℉/05℃~Set temp. |
41℉/05℃ |
E2 |
Higher setpoint limit |
Set temp.~77℉/25℃ |
64℉/18℃ |
E3 |
Temp.hysteresis |
01~18℉/01~10℃ |
05℉/03℃ |
E4 |
Comp.start delay time |
00~10Min |
2Min |
E5 |
Offset on room temp. |
-18~18℉/-10~10℃ |
00℉/00℃ |
E6 |
Offset on evap.temp. |
-18~18℉/-10~10℃ |
00℉/00℃ |
F1 |
Max.Defrost duration |
01~60Min |
20Min |
F2 |
Defrost interval time |
00~24Hr |
6Hr |
F3 |
Defrost temination temp. |
32~68℉/00~20℃ |
46℉/8℃ |
F4 |
Displaying during defrost |
00=Normal display 01=Last value before defrost |
00 |
CF |
Temperature unit |
℃=Celsius ℉=Fahrenheit |
℃ |
P1 |
Fan delay time |
01~10Min |
3Min |
LE |
Backlight mode control |
00=energy saving mode 01=energy disspation |
01 |
-
Mandy Lam
Lynn Mai -
Kay
Carmen Chan - Tel (0086)760-88787946