Loading
搜索
1/1
Number of views:
0
1
Description
"
"
Features
Mini sized and integrated intelligent temperature control.
Temperature Display / Temperature Control /
Value Storing/Self Testing /Parameter Locking
Technical Data
Temperature sensor: NTC, one sensor, 2 meters long, neither positive nor negative
Range of temperature display:-45~120℃(-49~248℉)
Accuracy:±1℃ /±2℉
Range of set temperature:-45~45℃(-49~113℉)
Factory default : 04℃ /39℉
Relay output contact capacity
Compressor: N. O. 30A/250VAC
Evap. Fan: N. O. 10A/250VAC
Light: N. O. 10A/250VAC
Demist: N. O. 10A/250VAC
Paramete
Paramete | Function | Set range | Default |
E1 | Lower set point limit |
-45℃
-49℉~set temp.
|
-31℉
-35℃
|
E2 | Higher set point limit |
45℃
113℉~set temp.
|
68℉
20℃
|
E3 | Temp. hysteresis |
01~10℃
02~18℉
|
7 ℉
4℃
|
E4 | Comp. Start delay time | 00~10min | 2 min |
E5 | Offset on room temp |
-20~20℃
-36~36℉
|
00℃
00℉
|
F1 | Max. Defrost duration | 01~90min | 20 min |
F2 | Defrost interval time | 0~24hr | 6hr |
F4 | Temperature display during defrosting |
00=Normal display
01 = Last value before defrost
02=display DEF
|
01 |
F5 | Fan control |
00=Parallel with comp.(stop when defrost)
01 = Continuous running (stop when defrost)
02= Parallel with comp. (Start when defrost)
03=keep running(start when defrost)
|
03 |
C1 | Warning of cabinet temperature and high temperature |
C2~45℃
113℉
|
45℃
113℉
|
C2 | Cabinet Temperature and Low Temperature Alarm |
-45℃
-49℉C1~
|
-40℃
-40℉
|
C3 | Alarm return error |
01~20℃
02~36℉
|
02℃
04℉
|
C4 | Alarm delay time | 00~90min | 30 min |
CF | Temperature unit | ℃=Celsius ℉=Fahrenheit | ℃ |