Features
Humidity display
Temperature control
Defrost control
Light control/ Power switch
Value storing/ Self-testing
Technical Data
Temperature display range: -45~99℃
Set temperature range: -45~+75℃
Accuracy: ±01℃
Temperature sensor: NTC, one sensor, 2mlong, neither positive nor negative
Compressor relay : 30A/250VAC
Light relay: 5A/250VAC
Dimension: 181mm( )×41mm(W)×68mm(D)
Mounting hole dimension: 138mm( )×32.5mm(W)
Parameters
Paramete |
Function |
Set range |
Default |
PA |
Menu password |
00~50~99 |
82 |
E1 |
Lowest set point limit |
-45℃~retain freshness set temp. |
-25℃ |
E2 |
Higher set point limit |
retain freshness set temp.~75℃ |
30℃ |
E3 |
hysteresis |
01~10℃ |
04℃ |
E4 |
Comp. start delay time |
00~10Min |
2Min |
E5 |
Offset on roomtemp sensor |
-20~20℃ |
00℃ |
E6 |
Offset on humidity sensor |
-20~20% |
00% |
P1 |
Light duration time |
00~180 min 00 is infinite length |
00Min |
C1 |
High temp. alarmvalue |
C2~75℃ |
45℃ |
C2 |
Low temp. alarm value |
-45 ℃~C1 |
-35℃ |
C3 |
Alarm delay time |
00~60min |
2min |
C4 |
Alarm hysteresis |
01~10 ℃ |
02℃ |
F1 |
Defrost cycle |
01~90min |
20min |
F2 |
Defrost interval |
00~24hours |
-
Mandy Lam
Lynn Mai -
Kay
Carmen Chan - Tel (0086)760-88787946
- TOP