Features of Function
Set time, countdown/ Temperature Display / Heating dehumidify Control / Refrigeration control/ Sequence control Self Testing
Specifications
1. Power supply: 220V~240VAC 50/60Hz
2. Temperature sensor: one sensor , 2m(L)
3. Humidity sensor: one sensor, 2m(L)
4. Count down time set range: 00:01~12:00 (Hour: Minutes)
5. Range of temperature displayed:-19~99℃ Accuracy:±1℃
Range of humidity displayed: 20%~99%RH Accuracy: ±3%RH
6. Dimension:150(Length)×93(Width)×59(Depth)mm
Mounting hole dimension:142.5(Length)×85.5(Width)mm
7. Temperature of the operating environment:-10~60℃
Relative Humidity:20%~90%(Non-condensing)
8. Relay output contact capacity
Compressor: N. O. 30A/250VAC(Can connect 1HP load, if more need to connect and AC contactor)
Heater: N. O. 16A/250VAC Dehumdify, refrigeration, heating fan: N. O. 10A/250VAC
-